Acrel Din Rail Dc Power Meter Applicated In Hongkong Charging Pile Company

更新時間:2023-04-13      點擊次數:440
 Abstract:

  Solar energy is a rapidly growing energy source in the world and the most easily available renewable energy source. The market share of the use of solar energy to transmit electricity to the grid is still growing. At the same time, grid companies usually require the photovoltaic grid-connected system to be an irreversible power generation system, that is, the electricity generated by the photovoltaic grid-connected system is consumed by the local load. It is self-generated and used. In the grid-connected power generation and energy storage system, with the external environment is constantly changing, in order to prevent the photovoltaic grid-connected system from generating reverse power, the system needs to perform reverse current detection, and regulate the power generation of the system by real-time monitoring of the power signal on the low-voltage outlet side of the distribution transformer power, so as to achieve the anti-backflow function of the photovoltaic grid-connected system. This article introduces the application of ACREL ACR10R and AWT100-4G in a pump industry in India

 

1. Project Overview
   Indian customers plan to produce inverters by themselves. They need inverters and energy meters for government tender. They need ACR10T to monitor the electricity consumption of the plant equipment and use electricity meters to detect the energy consumption of each device effectively. AWT100-4G use MQTT protocol to connect the platform


  
2. Technical Parameters

 

3.Wiring & Installation 


4. Network Topology

 

5. Installation Site


6.In conclusion
  ACR10R it has a variety of peripheral interface for user to choose: with RS485 communication interface, MODBUS-RTU protocol can meet the needs of communication network management; The function of “ remote signal" and “ remote control" of circuit breaker switch can be realized with switch quantity input and relay output. The interfaces with switch input and relay output can realize the remote signaling and remote control of the circuit breaker switch. It is very suitable for real-time power monitoring system with an LCD display and the panel buttons to realize the setting and control of parameters for PV inverter system.


Bibliography 
1.Solutions for enterprise micro-grid system    2021.04

安科瑞電氣股份有限公司
  • 聯系人:曹艷菊
  • 地址:上海市嘉定區育綠路253號
  • 郵箱:2880635303@qq.com
  • 傳真:86-021-69153967
關注我們

歡迎您關注我們的微信公眾號了解更多信息

掃一掃
關注我們
版權所有©2024安科瑞電氣股份有限公司All Rights Reserved    備案號:滬ICP備05031232號-90    sitemap.xml    總訪問量:99004
管理登陸    技術支持:化工儀器網    
電瓶車充電樁、電動汽車充電樁禁止非法改裝!
主站蜘蛛池模板: 黄色的视频网站在线观看| 四虎影在永久地址在线观看| 国产成人亚洲精品77| 久草免费在线色站| 欧美成人一区二区三区不卡视频| 国产在线精品一区二区| 成人亚洲国产综合精品91| 久色亚洲| 天堂69亚洲精品中文字幕| 免费观看美女视频的网站| 九九视频精品在线| 国产三级久久久精品三级| 国产99视频精品免视看9| 999久久精品国产| 王朝的女人在线观看免费完整 | 久久久蜜桃| 婷婷五月在线视频| 日韩综合色| 日本免费福利视频| 欧美中文字幕在线视频| 免费激情网站| 成人伊人青草久久综合网| 999成人国产精品| 天天干亚洲| 综合网激情| 久久99精品久久久久久秒播放器| 四虎影视最新网址| 日韩精品福利片午夜免费| 日本不卡一区二区| 奇米视频第四色| 人人草人人爽| 日本加勒比在线播放| 日韩成人综合网| 日韩在线看免费高清完整版| 日韩色综合| 日韩欧美成人免费中文字幕| 日韩高清一级| 深爱激情五月婷婷| 我的夫人2015中字幕| 五月天丁香婷婷开心激情五月 | www.四虎影视.com|